{"product_id":"rpb-safety-austausch-filterpatrone-fur-atemluftfilter-radex","title":"Replacement filter cartridge for Radex breathing-air filter","description":"\u003ch4\u003eRPB Safety APF3100 – Replacement filter cartridge for the Radex supplied-air respirator filter\u003c\/h4\u003e\u003cp\u003eThe RPB Safety APF3100 is the original replacement filter cartridge for the RPB Radex supplied-air respirator filter. It renews the system’s 6-stage filtration performance and removes moisture, odors and particles down to 0.5 micrometers from the compressed-air stream.\u003c\/p\u003e\u003cp\u003eThe cartridge is a safety-critical wear part. RPB requires replacement after three months or 400 operating hours at the latest—whichever comes first. Shorter intervals may be required in conditions of high humidity, heavy contamination or polluted incoming air.\u003c\/p\u003e\u003chr\u003e\u003ch4\u003eYour benefits at a glance\u003c\/h4\u003e\u003cdiv style=\"line-height:1.75;\"\u003e✅ Original RPB replacement cartridge\u003cbr\u003e✅ Precisely fits the Radex supplied-air respirator filter\u003cbr\u003e✅ 6-stage filtration\u003cbr\u003e✅ Filters moisture, odors and particles down to 0.5 µm\u003cbr\u003e✅ Quick and easy replacement\u003cbr\u003e✅ Supports reliable breathing-air treatment\u003cbr\u003e✅ Replacement indicator for maintenance planning\u003c\/div\u003e\u003chr\u003e\u003ch4\u003e📦 Scope of delivery\u003c\/h4\u003e\u003cdiv style=\"line-height:1.75;\"\u003e✔ One RPB Radex replacement filter cartridge APF3100\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eTechnical data\u003c\/h4\u003e\u003cdiv style=\"overflow-x:auto;border:1px solid #d9d9d9;border-radius:10px;\"\u003e\u003ctable style=\"width:100%;min-width:680px;border-collapse:separate;border-spacing:0;text-align:center;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"position:sticky;left:0;z-index:3;background:#e5e5e5;padding:12px;border-right:1px solid #d0d0d0;border-bottom:1px solid #c8c8c8;text-align:left;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#e5e5e5;padding:12px;border-bottom:1px solid #c8c8c8;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eAPF3100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eRPB Radex supplied-air respirator filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eFilter stages\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eParticle filtration\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003edown to 0.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;text-align:left;font-weight:600;\"\u003eReplacement interval\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003emax. 3 months or 400 operating hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eWhen must the cartridge be replaced?\u003c\/h4\u003e\u003cp\u003eThe cartridge must be replaced after three months or 400 operating hours at the latest. The replacement schedule applies regardless of whether the filter is used daily or only occasionally. It should be replaced sooner if the compressed air is humid or heavily contaminated.\u003c\/p\u003e\u003cdiv style=\"margin-top:16px;padding:14px 16px;background:#f3f3f3;border-radius:10px;\"\u003e\n\u003cstrong\u003e📌 Important:\u003c\/strong\u003e\u003cbr\u003eThe filter cartridge does not remove carbon monoxide. The breathing-air source must be suitable and, if necessary, monitored with a gas monitor.\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eFAQ – Frequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eDoes the APF3100 fit every supplied-air respirator filter?\u003c\/strong\u003e\u003cbr\u003eNo, it is designed for the RPB Radex.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan the cartridge be cleaned?\u003c\/strong\u003e\u003cbr\u003eNo. Once the replacement interval has expired, it must be replaced completely.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat happens if it is used for too long?\u003c\/strong\u003e\u003cbr\u003eFiltration performance decreases, and the safe operation of the supplied-air respirator system can no longer be guaranteed.\u003c\/p\u003e","brand":"rpb Safety","offers":[{"title":"Default Title","offer_id":52531720192347,"sku":"APF3100","price":26200.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/files\/ersatz-filterpatrone-atemluftfilter-radex-gvs-rpb-safety-apf-3100.jpg?v=1772895945","url":"https:\/\/ae6ea8-95.myshopify.com\/en-hu\/products\/rpb-safety-austausch-filterpatrone-fur-atemluftfilter-radex","provider":"ABS Strahltechnik","version":"1.0","type":"link"}