{"product_id":"rpb-safety-atemluft-klimagerat-c40","title":"C40 breathing-air conditioning unit for Nova 3, Nova 2000 blast helmets","description":"\u003ch4\u003eRPB Safety C40 – Air conditioner for cooling and heating supplied breathing air\u003c\/h4\u003e\u003cp\u003eThe RPB Safety C40 is a compact air conditioner for supplied-air respiratory protection systems. It allows the user to adjust the temperature of the supplied breathing air directly at the belt, making work more comfortable in hot or cold working conditions.\u003c\/p\u003e\u003cp\u003eA lever allows you to switch between cooling and heating mode. The C40 can cool the incoming breathing air by up to 29 °C or heat it by up to 18 °C. The airflow can also be adjusted using a separate regulator.\u003c\/p\u003e\u003chr\u003e\u003ch4\u003eYour Benefits at a Glance\u003c\/h4\u003e\u003cdiv style=\"line-height:1.75;\"\u003e✅ Cooling and heating function in one device\u003cbr\u003e✅ Cooling of the breathing air by up to 29 °C\u003cbr\u003e✅ Heating of the breathing air by up to 18 °C\u003cbr\u003e✅ Easy switching via lever\u003cbr\u003e✅ Continuously adjustable airflow\u003cbr\u003e✅ Very low weight of just 277 g without belt\u003cbr\u003e✅ 360° swiveling air inlet for convenient hose routing\u003cbr\u003e✅ Robust construction for demanding industrial applications\u003cbr\u003e✅ Low maintenance requirements\u003cbr\u003e✅ Suitable for RPB Nova 3 and Nova 2000\u003c\/div\u003e\u003chr\u003e\u003ch4\u003e📦 Scope of Delivery\u003c\/h4\u003e\u003cdiv style=\"line-height:1.75;\"\u003e✔ RPB Safety C40 air conditioner\u003cbr\u003e✔ Belt\u003cbr\u003e✔ Connection design according to product configuration\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eTechnical Data\u003c\/h4\u003e\u003cdiv style=\"overflow-x:auto;border:1px solid #d9d9d9;border-radius:10px;\"\u003e\u003ctable style=\"width:100%;min-width:680px;border-collapse:separate;border-spacing:0;text-align:center;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"position:sticky;left:0;z-index:3;background:#e5e5e5;padding:12px;border-right:1px solid #d0d0d0;border-bottom:1px solid #c8c8c8;text-align:left;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"background:#e5e5e5;padding:12px;border-bottom:1px solid #c8c8c8;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eC40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eup to 29 °C below inlet temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eHeating Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eup to 18 °C above inlet temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eOperating Pressure\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003e55–80 psi \/ approx. 3.8–5.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eAir Requirement\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eapprox. 25 cfm \/ approx. 708 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003e277 g without belt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#fff;padding:10px 12px;border-right:1px solid #e0e0e0;border-bottom:1px solid #e8e8e8;text-align:left;font-weight:600;\"\u003eApproval\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;border-bottom:1px solid #e8e8e8;\"\u003eEN 14594:2005, Class 3B\/4B in an approved combination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"position:sticky;left:0;background:#f7f7f7;padding:10px 12px;border-right:1px solid #e0e0e0;text-align:left;font-weight:600;\"\u003eArticle Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px 12px;\"\u003e03-502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eHow It Works\u003c\/h4\u003e\u003cp\u003eThe C40 operates according to the vortex tube principle. Part of the supplied compressed air is used for temperature separation, while the required breathing-air flow is directed to the helmet. Therefore, in addition to the air requirements of the respiratory protection system, the compressed-air supply must also cover the air conditioner's additional consumption.\u003c\/p\u003e\u003cdiv style=\"margin-top:16px;padding:14px 16px;background:#f3f3f3;border-radius:10px;\"\u003e\n\u003cstrong\u003e📌 Important:\u003c\/strong\u003e\u003cbr\u003eThe C40 may only be operated within a breathing-air configuration approved by the manufacturer. An undersized compressed-air supply may result in the airflow to the helmet falling below the required level.\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eMaintenance and Care\u003c\/h4\u003e\u003cdiv style=\"line-height:1.75;\"\u003e✔ Clean the silencer regularly and replace it if necessary\u003cbr\u003e✔ Keep the air inlet and connections clean\u003cbr\u003e✔ Check the function of the temperature lever and air regulator\u003cbr\u003e✔ Protect the device from abrasive media and paint mist\u003cbr\u003e✔ Use only approved breathing-air hoses\u003c\/div\u003e\u003chr\u003e\u003ch4\u003eFAQ – Frequently Asked Questions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eCan the C40 heat and cool at the same time?\u003c\/strong\u003e\u003cbr\u003eNo, a lever is used to switch between cooling and heating mode.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow much air does the C40 require?\u003c\/strong\u003e\u003cbr\u003eApproximately 25 cfm or around 708 l\/min at 55–80 psi.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the C40 compatible with the Nova 3 and Nova 2000?\u003c\/strong\u003e\u003cbr\u003eYes, in the respective approved hose and connection configuration.\u003c\/p\u003e","brand":"rpb Safety","offers":[{"title":"Default Title","offer_id":52531746799963,"sku":"03-502","price":534.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0876\/8526\/7803\/files\/atemluft-klimageraet-c40-gvs-rpb-safety-03-502.jpg?v=1772896811","url":"https:\/\/ae6ea8-95.myshopify.com\/da-ie\/products\/rpb-safety-atemluft-klimagerat-c40","provider":"ABS Strahltechnik","version":"1.0","type":"link"}